FLOW IntraCellular Staining Kit (IC FLOW)

Cat# MBS668927-1

Size : 1Kit

Brand : MyBiosource

Contact local distributor :


Phone : +1 850 650 7790

FLOW Intracellular (FLOW) Staining Kit

For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS668927

The Intracellular FLOW Staining Kit allows detection antibodies to access the intracellular protein in Flowcytometry analysis. This kit is specially formulated to reduce non-specific staining of fluorochrome-labelled antibodies and to increase fluorescence… More details

Product Overview

Online Datasheet in PDF
Product Name
FLOW IntraCellular, Staining Kit
Full Product Name
FLOW IntraCellular Staining Kit (IC FLOW)
Preparation and Storage
Store at 2-8 degree C
Kit Components
Fixation Buffer (1X) - 60 ml, Permeabilization Buffer (10X)- 2 X 60 ml, Staining Buffer - (1X) - 60 ml

Product Categories/Family for FLOW IntraCellular staining kit

Kits and Reagents; Flowcytometry staining Kits
Applications Tested/Suitable for FLOW IntraCellular staining kit
Flow Cytometry (FC/FACS)
Application Notes for FLOW IntraCellular staining kit
Protocol: 1. Determine number of cells required for staining. Each sample contains 0.5 -1 x 10^6 cells in 50ul of media or staining buffer. The following controls are needed for the experiment. Unstained cells (no antibodies were added), cells with isotype control and cells with secondary antibody (if secondary antibody was used). 2. Cetrifuge cells at 1000 RPM for 10 minutes and decant supernatant. 3. Resuspend cells with appropriate volume of Fixation buffer. Incubate in ice for for 30 minutes. 4. Centrifuge cells 1000 RPM for 10 minutes and decant supernatant. 5. Resuspend pellet with appropriate volume of 1X permeabilization buffer. 6. Aliquote 1x10^6 cells in 50 ul to the desired number of flow tubes. Dilute primary antibodies in 50 ul of 1X permeabilization buffer. Add diluted antibodies into 50 ul of cells. Mix antibodies in cells suspension thoroughly. 7. Incubate in ice for 30 minutes. Wash cells in 2-3 ml of 1X permeabilization buffer. Centrifuge 1000 RPM for 10 minutes. Decant supernatant carefully. If primary antibody is fluorescent-labeled, resuspent pellet in 300-400 ul of staining buffer, analyze samples. Protected from light. If primary antibody is not labeled, proceed with step 8. 8. Dilute secondary antibody (PE, FITC, APC or biotin labeled) in 50 ul of permeabilization buffer per sample. 9. Resuspend cells in diluted secondary antibody. Incubate in ice for 30 minutes. (protected from light). 10. Wash cells in 3-4 ml of permeabilization buffer. Cetrifuge at 1000 RPM for 10 minutes. Decant supernatant. 11. After decanting, add 300-400ul of Staining Buffer to each tube. If not analyzing same day, samples can be stored over night in dark at 4 degrees C. Samples can be analyzed in Flow Cytometer according to the manufacturer protocol.

Testing Data of FLOW IntraCellular staining kit

Intracellular Staining of PBMC. 0.5 ug of antibody was used. Red: Human TLR3 PE. Green: Isotype control (mouse IgG1PE) was used. Intracellular FLOW kit was used.
FLOW Staining Kit – Cat# MBS668927

Other Notes

Small volumes of FLOW IntraCellular staining kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.