Rabbit Oxidized Low Density Lipoprotein (OxLDL) (Competitive ELISA) ELISA Kit
Cat# MBS2710128
Brand : MyBiosource
Oxidized Low Density Lipo (OxLDL) ELISA Kit for Rabbit
For Research Use Only. Not for use in diagnostic procedures. Catalog #: MBS2710128Principle of the Assay: This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to OxLDL has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled OxLDL and… More details
Please Inquire
Product Overview
Online Datasheet in PDFProduct Name
Oxidized Low Density Lipoprotein (OxLDL), ELISA Kit
Full Product Name
Rabbit Oxidized Low Density Lipoprotein (OxLDL) (Competitive ELISA) ELISA Kit
Product Gene Name
OxLDL elisa kit
Product Synonym Names
OL; ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL)
Species Reactivity
Rabbit
Assay Type
Quantitative Competitive
Samples
Rabbit serum, plasma and other biological fluids
Detection Range
12.35-1,000ng/mL
Sensitivity
< 4.34ng/mL
Specificity
This assay has high sensitivity and excellent specificity for detection of OxLDL. No significant cross-reactivity or interference between OxLDL and analogues was observed.
Preparation and Storage
4 degree C for 1 month/ -20 degree C for long-term(within shelf life). Shelf life is one year
Inter-assay Precision
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level OxLDL were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-assay Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level OxLDL were tested 20 times on one plate, respectively. Intra-Assay: CV<10%
Supply Chain Verification
Manufactured in a lab with traceable raw materials. Bulk orders can typically be prepared to the customer’s specifications, please inquire.
Product Categories/Family for OxLDL elisa kit
Metabolic pathway
ISO Certification
Manufactured in an ISO 9001:2008 and ISO 13485:2003 Certified Laboratory.
Other Notes
Small volumes of OxLDL elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for OxLDL purchase
MBS2710128 is a ready-to-use microwell, strip-or-full plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Oxidized Low Density Lipoprotein (OxLDL) ELISA Kit target analytes in biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing OxLDL. The ELISA analytical biochemical technique of the MBS2710128 kit is based on OxLDL antibody-OxLDL antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect OxLDL antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, OxLDL. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Additional Details
NCBI/Uniprot data below describe general gene information for OxLDL. It may not necessarily be applicable to this product.
Protein Family
Oxidized low-density lipoprotein receptor
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.
Product Note
Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual, it is intended to serve as an example only. Please refer to the instructions For Use provided with the assay kit for precise details.


